-40%
Probe Master 4232 Differential Probe 1400 Volts 1:10/100, 25 MHz, USA seller
$ 166.32
- Description
- Size Guide
Description
PRODUCT DESCRIPTIONDifferential Probe for Power Management- Model 4232
The 4232 is designed to safely analyze floating signals. The built in amplifier scales and converts the high voltage differential
input to a low, voltage single-ended BNC output, compatible with any oscilloscope. The inputs are useful in
measurements of power semiconductor circuits, robotic drives, NC machines and the latest switching circuits.
Applications
-Switching Power Supply Design
-Motor Drive Design
-Electronic Ballast Design
-CRT Display Design
Features
-Up to +/-1400V (DC +Peak AC) Differential
and Common Mode
-Safety Certified
-Economical cost
Cost Included
-Red & Black Sprung Hooks
-Calibration Certificate
-4ea AA Batteries
-9VDC Adapter
Model 4232 Specifications
Bandwidth
DC to 25 MHz (-3dB)
Attenuation Ratio
1:10/100
Accuracy
+/- 2%
Rise Time
14ns
Input Impedance
4 Mohm//5.5pF each side to ground
Input Voltage**
-Category
-Differential Range
-Common Mode Range
-Absolute Max. Voltage(Differential or Common Mode)
Cat III
70 Vrms and +/- 70V(DC + Peak AC)@ 1/10
700 Vrms and +/-700V(DC + Peak AC @ 1/100
700 Vrms and +/-700V(DC + Peak AC)@ 1/10 & 1/100
1000 Vrms and +/-1400V(DC + Peak AC@ 1/10 & 1/100
Output Voltage
-Swing
-Offset (typical)
-Noise (typical)
-Source Impedance (typical)
+/- 7V( into 50 kohm load)
<+/-5mV
0.7mVrms
50 ohm (for using 1 Mohm input system oscilloscope)
CMMR (typical)
-80dB @ 50 Hz, -60dB @ 20kHz
Ambient Operating Temperature
-10 to 40 degrees centigrade
Ambient Storage Temperature
-30 to 70 degrees centigrade
Ambient Operating Humidity
Up to 85% RH
Ambient Storage Humidity
Up to 85% RH
Power Requirements*
-Standard- 4 x AA Cells, 9VDC/40mA Mains Adapter (Both Included)
-Options- USB Power cord Power leads
Length of BNC Cable
37"
Length of Input Leads
17"
Dimension
7 1/4" x 2 3/4" x 1"
Weight
.583 lb
Plugs 4mm Banana plugs
- Use with accessories below